Thanks Paul and everyone else we got things to work on our lab with the 
following values, similar to yours Paul

STPMODE YES
STPZONE NO
TIMEZONE=E.09.00.00
OPERATOR NOPROMPT



Andy, we have STP setup to provide UTC (GMT) to the lpars/hardware.  Them we 
use the offset in the CLOCK member to set the "local" time for the lpars.  We 
have two CECs running lpars on US central time and lpars running on UK time.  I 
hope this helps.

Our CLOCK member for the US lpars with DST:
OPERATOR NOPROMPT
TIMEZONE W.05.00.00
STPMODE  YES
STPZONE  NO

Our CLOCK member for the UK lpars with DST:
OPERATOR NOPROMPT
TIMEZONE E.01.00.00
STPMODE  YES
STPZONE  NO

Thanks..