On Tue, 21 Nov 2017 19:14:30 -0600, Edward Gould wrote:
>> 
>>>> In days of yore panel definitions for SPF (now known as ISPF) were VB.  
>>>> Abruptly
>>>> they changed to FB.  Disruptively -- it broke all my customized panels.  
>>>> Cognoscenti
>>>> surmised this was an accommodation to SMP(/E) and IEBUPDTE.
>>> 
>>> I will admit that I am leary of that explanation, ...
>>>> 
>> Why?
>
>Way back then concatenation of VB and FB wasn’t available.
>
But that's exactly what broke my customized panels when IBM changed
their panels from VB to FB.  Concatenating mine with theirs suddenly
failed where it had worked as long as IBM's panels were VB.

-- gil

----------------------------------------------------------------------