I use 60 % free space. In this way, the entire contents can be replaced (if 
needed) and also allows for some growth.


-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Blake, Daniel J [CTR]
Sent: Tuesday, October 2, 2018 5:55 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: S106 abends after copying into LINKLIST

When building a new system or adding maintenance I go back through all LNK, LPA 
and APF libraries making sure they all have at least 20% free space. If for no 
other reason getting setup for the next maintenance cycle.  When I'm bored, 
which is almost never, I'll check every data set on the RES volume for free 
space.


;-D an


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Vernooij, Kees (ITOPT1) - KLM
Sent: Tuesday, October 02, 2018 2:38 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: S106 abends after copying into LINKLIST

You can also avoid both by allocating it large enough: calculate what you need 
during the life of the IPL, double, triple or whatever it and you can sleep 
quietly. What do a few 1000 cyls cost these days?

Kees.

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU]
> On Behalf Of Ed Jaffe
> Sent: 02 October, 2018 8:33
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: S106 abends after copying into LINKLIST
>
> On 10/1/2018 1:34 PM, Jesse 1 Robinson wrote:
> > There are two separate problems here. (1) A link list library taking
> > a
> new extent after IPL. (2) An LLA-managed library having contents moved
> by either compress or reload.
> >
> > (1) Can be avoided by simply not defining any secondary extent, i.e.
> specifying a secondary of zero. Getting more than one extent to
> satisfy the original allocation is not a problem as long as no
> additional extent is allowed afterward. If a new extent is truly
> needed to hold enlarged content, then link list update can be used.
> >
> > (2) Seems to be OP's issue. LLA REFRESH can handle the consequences
> > of
> dynamic update within the original (IPL time) extent(s). Note that
> REFRESH is needed on all sharing systems.
>
> I never liked defining secondary of zero. I realize it's IBM's
> recommendation, but it all but ensures a compress will be performed
> when the library fills up. I've had systems crash either during or
> after such a compress -- sometimes with disastrous consequences!
>
> I would much rather take a new extent for one relinked module than
> risk corrupting the *ENTIRE LIBRARY* with a "live" compress using DISP=SHR.
> Of course, periodic compress of LNKLST PDS libraries is not a bad idea
> when done under controlled circumstances: i.e., "quiet" time and LLA
> on all sharing systems has been shut DOWN. Also, I like to STEPLIB any
> IEBCOPY job to a recent *copy* of SYS1.LINKLIB to ensure IEBCOPY
> program parts are not moved during the compress... BTDTGTS!!
>
>
> --
> Phoenix Software International
> Edward E. Jaffe
> 831 Parkview Drive North
> El Segundo, CA 90245
> https://apac01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww
> .phoenixsoftware.com%2F&amp;data=02%7C01%7Callan.staller%40HCL.COM%7Ce
> 5b22f96eb864d1712df08d62855ad14%7C189de737c93a4f5a8b686f4ca9941912%7C0
> %7C0%7C636740745807628066&amp;sdata=%2Bq5m1B%2BWqBPQLMrX%2BwfqTsTuniUY
> PzuVswtZNlub6i8%3D&amp;reserved=0
>
>
> ----------------------------------------------------------------------
> --
> --------
> This e-mail message, including any attachments, appended messages and
> the information contained therein, is for the sole use of the intended
> recipient(s). If you are not an intended recipient or have otherwise
> received this email message in error, any use, dissemination,
> distribution, review, storage or copying of this e-mail message and
> the information contained therein is strictly prohibited. If you are
> not an intended recipient, please contact the sender by reply e-mail
> and destroy all copies of this email message and do not otherwise
> utilize or retain this email message or any or all of the information
> contained therein. Although this email message and any attachments or
> appended messages are believed to be free of any virus or other defect
> that might affect any computer system into which it is received and
> opened, it is the responsibility of the recipient to ensure that it is
> virus free and no responsibility is accepted by the sender for any
> loss or damage arising in any way from its opening or use.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
********************************************************
For information, services and offers, please visit our web site: 
https://apac01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.klm.com&amp;data=02%7C01%7Callan.staller%40HCL.COM%7Ce5b22f96eb864d1712df08d62855ad14%7C189de737c93a4f5a8b686f4ca9941912%7C0%7C0%7C636740745807628066&amp;sdata=UDqmNCuPUwPyEv7OtmfBjGSDghBKR80BuvFvGxhEHXo%3D&amp;reserved=0.
 This e-mail and any attachment may contain confidential and privileged 
material intended for the addressee only. If you are not the addressee, you are 
notified that no part of the e-mail or any attachment may be disclosed, copied 
or distributed, and that any other action related to this e-mail or attachment 
is strictly prohibited, and may be unlawful. If you have received this e-mail 
by error, please notify the sender immediately by return e-mail, and delete 
this message.

Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its 
employees shall not be liable for the incorrect or incomplete transmission of 
this e-mail or any attachments, nor responsible for any delay in receipt.
Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch 
Airlines) is registered in Amstelveen, The Netherlands, with registered number 
33014286
********************************************************


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to