I can't help with the JES side. We have a CTC between 2 VM's. the LINKDEF in 
RSCS CONFIG on one side is:

LINKDEF VM4 TYPE NJE   LINE 92D0 NODE VM4 AST RETRY

Regards,
Richard Schuh

 -----Original Message-----
From:   The IBM z/VM Operating System [mailto:[EMAIL PROTECTED]  On Behalf Of 
Dave Jones
Sent:   Thursday, April 20, 2006 11:19 AM
To:     IBMVM@LISTSERV.UARK.EDU
Subject:        RSCS<->z/OS question....

Hi, Gang....

I have a problem I'm hoping somebody on this list can assist me 
with..... I need to configure an NJE connection between a first level 
RSCS server and a 2nd level z/OS guest. The client wants to be able to 
submit z/OS batch type jobs from CMS user id on the 1st level VM system 
to the 2nd level z/OS one, and get the prt/pun output back to the CMS user.

I have a virtual CTC connection set up between VM and z/OS already, and 
z/OS can see the CTC, vary it online, etc. What I am missing are the 
RSCS and JES2 (I think, or maybe I need to use VTAM?) line configuration 
statements.

Does anyone have a set of working examples they would be willing to 
share? TIA.

Have a good one.

DJ