Thanks for the help.
 
I found the following:
 
ST:VMFP2P2760I PUT2PROD processing started for SEGMENTS

ST:VMFSET2760I VMFSETUP processing started for SERVP2P BASE

ST:VMFUTL2205I Minidisk|Directory Assignments:

ST:            String    Mode  Stat  Vdev  Label/Directory

ST:VMFUTL2205I --------  A      R/W  191   MNT191

ST:VMFUTL2205I --------  B      R/W  5E5   MNT5E5

ST:VMFUTL2205I --------  C      R/W  2CC   MNT2CC

ST:VMFUTL2205I --------  D      R/W  51D   MNT51D

ST:VMFUTL2205I --------  S      R/O  190   MNT190

ST:VMFUTL2205I --------  Y/S    R/O  19E   MNT19E

ST:VMFSET2760I VMFSETUP processing completed successfully

ST:VMFBLD2760I VMFBLD processing started

ST:VMFBLD1851I Reading build lists

ST:VMFBLD2182I Identifying new build requirements

ST:VMFBLD2182I New build requirements identified

ST:VMFBLD2180I There are 1 build requirements remaining

ST:VMFBLD2760I VMFBLD processing completed successfully

ST:VMFP2P2760I PUT2PROD processing started for segment HELPSEG

ST:ICH70001I BLDSEG   LAST ACCESS AT 13:30:09 ON MONDAY, OCTOBER 15,
2007       
ST:BLDSEG  : HCPLNM102E DASD 02C4 forced R/O; R/W by MAINT

ST:BLDSEG  : HCPLNM102E DASD 02A6 forced R/O; R/W by MAINT

ST:BLDSEG  : HCPLNM102E DASD 02A4 forced R/O; R/W by MAINT

ST:BLDSEG  : HCPLNM102E DASD 02A2 forced R/O; R/W by MAINT

ST:BLDSEG  : HCPLNM102E DASD 02D2 forced R/O; R/W by MAINT

ST:BLDSEG  : HCPLNM103E DASD 0194 forced R/O; R/W by MAINT, R/O by
LGLOPR       
ST:AUTO LOGON  ***       BLDSEG   USERS = 22

ST:HCPCLS6056I XAUTOLOG information for BLDSEG: The IPL command is

ST:            verified by the IPL command processor.

ST:BLDSEG  : z/VM V5.2.0    2007-06-28 19:19

ST:BLDSEG  : Ready; T=0.01/0.01 12:11:18

ST:BLDSEG  : CMS

ST:HCPQCS150A User BLDSEG has issued a VM read

ST:BLDSEG  : Ready; T=0.01/0.01 12:11:28

ST:BLDSEG  : VMFBLD2760I VMFBLD processing started

ST:BLDSEG  : VMFBLD1851I Reading build lists

ST:BLDSEG  : VMFBLD2182I Identifying new build requirements

ST:BLDSEG  : VMFBLD2182I No new build requirements identified

ST:BLDSEG  : VMFBLD1851I (1 of 1) VMFBDSEG processing SEGBLIST EXC00000

ST:D, target is BUILD

ST:BLDSEG  :             51D (D)

ST:BLDSEG  : VMFBDS2115I Validating segment HELPSEG

ST:BLDSEG  : VMFSET2204I Linking MAINT 3C4 as 3C4 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03C4 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3C2 as 3C2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03C2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3D2 as 3D2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03D2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3A6 as 3A6 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03A6 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3A4 as 3A4 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03A4 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3A2 as 3A2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03A2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3B2 as 3B2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03B2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 49E as 49E with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 049E forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 19D as 19D with the link mode MR

ST:BLDSEG  : DASD 019D LINKED R/W; R/O BY    16 USERS

ST:BLDSEG  : VMFSET2204I Linking MAINT 490 as 490 with the link mode MR

ST:BLDSEG  : VMFSET2204I Linking MAINT 493 as 493 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 0493 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 400 as 400 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 0400 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 402 as 402 with the link mode MR

ST:BLDSEG  : HCPLNM103E DASD 0402 forced R/O; R/W by MAINT, R/O by    13

ST:users

ST:BLDSEG  : VMFBDS2002I A DEFSEG command will be issued for 1

ST:segment(s).

ST:BLDSEG  : VMFBDS2219I Processing object HELPSEG.SEGMENT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3C4 as 3C4 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03C4 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3C2 as 3C2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03C2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3D2 as 3D2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03D2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3A6 as 3A6 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03A6 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3A4 as 3A4 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03A4 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3A2 as 3A2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03A2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 3B2 as 3B2 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 03B2 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 49E as 49E with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 049E forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 19D as 19D with the link mode MR

ST:BLDSEG  : DASD 019D LINKED R/W; R/O BY    16 USERS

ST:BLDSEG  : VMFSET2204I Linking MAINT 490 as 490 with the link mode MR

ST:BLDSEG  : VMFSET2204I Linking MAINT 493 as 493 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 0493 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 400 as 400 with the link mode MR

ST:BLDSEG  : HCPLNM102E DASD 0400 forced R/O; R/W by MAINT

ST:BLDSEG  : VMFSET2204I Linking MAINT 402 as 402 with the link mode MR

ST:BLDSEG  : HCPLNM103E DASD 0402 forced R/O; R/W by MAINT, R/O by    13

ST:users

ST:BLDSEG  : DMSACP726I 19D O released

ST:BLDSEG  : DMSGEN1279E Error(s) occurred during SEGGEN processing.

ST:BLDSEG  : VMFBDS1965E The command, SEGGEN HELPSEG PSEG A SYSTEM SEGID

ST:D2 ( NOTYPE, failed

ST:BLDSEG  :             with return code 32

ST:BLDSEG  : VMFBLD1851E (1 of 1) VMFBDSEG completed with return code

ST:100. Some objects were

ST:BLDSEG  :             not built

ST:BLDSEG  : VMFBLD2180I There are 1 build requirements remaining

ST:BLDSEG  : VMFBLD2760I VMFBLD processing completed unsuccessfully

ST:BLDSEG  : Ready(00008); T=0.68/0.74 12:11:30

ST:USER DSC   LOGOFF AS  BLDSEG   USERS = 21    FORCED BY MAINT

ST:BLDSEG  : RDR FILE 0002 SENT FROM BLDSEG   CON WAS 0002 RECS 0071 CPY

ST:001 T NOHOLD NOKEEP

ST:DASD 019D LINKED R/W; R/O BY    16 USERS

SV:VMFP2P1965E The command, CP SEND BLDSEG EXEC VMFBLD PPF SEGBLD
ESASEGS    
SV:            SEGBLIST HELPSEG.SEGMENT LINK (SERVICED NOLOG, failed
with    
SV:            return code 8

ST:VMFP2P2760I PUT2PROD processing completed unsuccessfully for SEGMENTS

 

 Jerry Whitteridge

Mainframe Engineering

Safeway Inc

925 951 4184

[EMAIL PROTECTED]

 


________________________________

        From: The IBM z/VM Operating System
[mailto:[EMAIL PROTECTED] On Behalf Of David Kreuter
        Sent: Wednesday, February 13, 2008 2:15 PM
        To: IBMVM@LISTSERV.UARK.EDU
        Subject: Re: PUT2PROD Error
        
        

        Hi: From MAINT do a VMFVIEW PUT2PROD. Then do a PF2 "ALL" and
find the messages you sent below.
        Right around those messages should be details on why it failed.
Look for errors from the userid
        BLDSEG in this log. Let us know what you find.
        David Kreuter
        
        
        -----Original Message-----
        From: The IBM z/VM Operating System on behalf of Jerry
Whitteridge
        Sent: Wed 2/13/2008 2:24 PM
        To: IBMVM@LISTSERV.UARK.EDU
        Subject: [IBMVM] PUT2PROD Error
        
        I'm running service to apply ptf UM31784 (we have some DS8300's
coming
        in) and when I ran the put2prod step I got the following
message:
        
        
************************************************************************
        
        ****             PUT2PROD              USERID: MAINT
****
        
        
************************************************************************
        
        ****            Date: 02/13/08            Time: 12:08:15
****
        
        
************************************************************************
        
        SV:VMFP2P1965E The command, CP SEND BLDSEG EXEC VMFBLD PPF
SEGBLD
        ESASEGS  
        SV:            SEGBLIST HELPSEG.SEGMENT LINK (SERVICED NOLOG,
failed
        with  
        SV:            return code 8     
        
        along with
        
        VMFP2P2760I PUT2PROD processing completed unsuccessfully for
SEGMENTS
        
        
        I have no idea what to do with this info ! Any help would be
        appreciated.
        
        
        
         Jerry Whitteridge
        
        Mainframe Engineering
        
        Safeway Inc
        
        925 951 4184
        
        [EMAIL PROTECTED]
        
        
        
        "Email Firewall" made the following annotations.
        
------------------------------------------------------------------------
------
        
        Warning:
        All e-mail sent to this address will be received by the
corporate e-mail system, and is subject to archival and review by
someone other than the recipient.  This e-mail may contain proprietary
information and is intended only for the use of the intended
recipient(s).  If the reader of this message is not the intended
recipient(s), you are notified that you have received this message in
error and that any review, dissemination, distribution or copying of
this message is strictly prohibited.  If you have received this message
in error, please notify the sender immediately.  
        
        
========================================================================
======
        
        


"Email Firewall" made the following annotations.
------------------------------------------------------------------------------

Warning: 
All e-mail sent to this address will be received by the corporate e-mail 
system, and is subject to archival and review by someone other than the 
recipient.  This e-mail may contain proprietary information and is intended 
only for the use of the intended recipient(s).  If the reader of this message 
is not the intended recipient(s), you are notified that you have received this 
message in error and that any review, dissemination, distribution or copying of 
this message is strictly prohibited.  If you have received this message in 
error, please notify the sender immediately.   
 
==============================================================================

Reply via email to