>Thanks, I changed some locations but none dealing with spool. So I
>should be ok with a WARM start. I think I will take your advice and
>RESERVE the SLOTS right after the last spool for additional spool. BTW,
>is there a practical limit on the number of SLOTS that can be defined?

You can define up to 255 slots.

In general, RESERVED slots are not automatically defined for unspecified
slot numbers, but any "gaps" in your slot numbers will be defined as
RESERVED slots.

For example,if you have the following CP_Owned statements:

          CP_Owned   Slot   1  530RES
          CP_Owned   Slot   2  SPOOL1
          CP_Owned   Slot   3  SPOOL2
          CP_Owned   Slot   7  PAGE1

Slots 4, 5, and 6 will be defined as RESERVED. While this is handy, and
could help you out in a pinch, I'd recommend actually entering statements
for the RESERVED slots so you can see what is available at a glance.

John Franciscovich