>Thanks, I changed some locations but none dealing with spool. So I >should be ok with a WARM start. I think I will take your advice and >RESERVE the SLOTS right after the last spool for additional spool. BTW, >is there a practical limit on the number of SLOTS that can be defined?
You can define up to 255 slots. In general, RESERVED slots are not automatically defined for unspecified slot numbers, but any "gaps" in your slot numbers will be defined as RESERVED slots. For example,if you have the following CP_Owned statements: CP_Owned Slot 1 530RES CP_Owned Slot 2 SPOOL1 CP_Owned Slot 3 SPOOL2 CP_Owned Slot 7 PAGE1 Slots 4, 5, and 6 will be defined as RESERVED. While this is handy, and could help you out in a pinch, I'd recommend actually entering statements for the RESERVED slots so you can see what is available at a glance. John Franciscovich z/VM Development