HCP1010W  NO CONSOLE AVAILABLE.
Explanation:  The indicated disabled wait state PSW is loaded when an
operational primary or alternate operator's console cannot be found.
If you were running in virtual mode, CONMODE was not set to 3270.
System Action:  The system enters a disabled wait state (wait state code =
1010). If using the Stand-Alone Program Loader (SAPL), all registers
contain
the values held at the time the wait state was entered. Register 2 contains
the console device address.
Operator Response:  There is probably a hardware malfunction. Notify your
system support personnel. Verify that the RIOGEN macro instruction properly
defined the primary and alternate system consoles.
If you were running in virtual mode, enter the TERMinal CONMODE 3270
command,
and re-IPL.
If using SAPL, either specify the correct console address on the LOADPARM
parameter of the IPL command or specify the correct console address using
the
'CONS=' IPL parameter on the SAPL menu screen. Refer to Overriding
Stand-Alone
Program Loader Defaults in z/VM: CP Planning and Administration.
If the problem persists, contact your IBM Support Center personnel to
diagnose
and correct the hardware error.
Doug Breneman z/VM Development IBM Endicott


                                                                       
  From:       "Martin, Terry R. (CMS/CTR) (CTR)" <[EMAIL PROTECTED]>
                                                                       
  To:         IBMVM@LISTSERV.UARK.EDU                                  
                                                                       
  Date:       09/12/2008 04:27 PM                                      
                                                                       
  Subject:    WAIT STATE                                               
                                                                       





Hi

I am trying to bring up a new VM LPAR and I am receiving a DISABLED WAIT
STATE CODE: 1010.

Any ideas?

Thank You,

Terry Martin
Lockheed Martin - Information Technology
z/OS & z/VM Systems - Performance and Tuning
Cell - 443 632-4191
Work - 410 786-0386
[EMAIL PROTECTED]

Reply via email to