On Wednesday, 03/25/2009 at 03:54 EDT, Dieltiens Geert 
<geert.dielti...@inf.vanbreda.be> wrote:

> I made that device available to a VM in another LPAR on the same CEC, 
and there 
> the IPL worked.
> Our 3 LPARs share the same Escon channels to an EMC box. Each LPAR only 
uses 
> it's own set of DASD devices (the other devices are set offline 
according to 
> SYSTEM CONFIG "OFFLINE_AT_IPL").
> 
> In the production LPAR I see msgs like this on the OPERATOR console:
> HCPMHT2153I DASD  B03C I/O CANCELLED DUE TO A MISSING INTERRUPT
> They started appearing since the moment that I IPL'd another VM in 
another LPAR 
> last weekend. I thought that maybe some devices were being used in both 
LPARs, 
> but I checked, and that's not the case.
> 
> Maybe EMC can find out more...

I have seen odd I/O incidents (tho not on EMC) when the number of devices 
defined in an I/O configuration exceeds the number supported by the 
control unit.  E.g. every dasd chpid with every device on the chpid 
defined to all the LPARs.  As soon as a device "beyond the limit" is used, 
it pulls the device away from whoever had it first.

But working it through EMC will be good.

Alan Altmark
z/VM Development