On Wednesday, 03/25/2009 at 02:11 EDT, Dieltiens Geert 
<geert.dielti...@inf.vanbreda.be> wrote:
> We have been using our current DASD setup for about 5 months now, with 
no 
> problems, until a couple of days ago. We have 896 (256+256+256+128) 
devices on 
> the Escon channels, using 4 control units, which PTK shows as 3990-6. 
AFAIK 
> this should all be nicely within the IBM and EMC limits.
> What puzzles me is that we do millions of IOs to all those devices, but 
the 
> problem only occurs with the IPL command in a virtual machine. Is there 
some 
> special kind of IO involved with IPL?

For a real (LPAR) IPL, yes, it is a special I/O.  For virtual IPL, CP just 
reads the IPL records from the [real or virtual] disk, starts the I/O and 
loads the initial PSW.

Alan Altmark
z/VM Development
IBM Endicott