Having just spent the past several months of my life deeply immersed in 
all thing SCIF, I can say Kris is right.  When a guest issues a read, CP 
checks if the guest's secondary is functional.  If it is not, a CP READ is 
also made pending.  To be functional the secondary must be connected or, 
if disconnected, must have an IUCV connection to *MSG or *MSGALL ... Perry

Perry Ruiter
250-658-6517