Not on 0801 either.

Frank M. Ramaekers Jr.
Systems Programmer                   MCP, MCP+I, MCSE & RHCE
American Income Life Insurance Co.   Phone: (254)761-6649
1200 Wooded Acres Dr.                Fax:   (254)741-5777
Waco, Texas  76710
        
-----Original Message-----
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Huegel, Thomas
Sent: Tuesday, September 08, 2009 1:49 PM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: NUCXDROP

I don't see either NUCXDROP or NUCXLOAD modules on my 5.4 RSU802. 

-----Original Message-----
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Marcy Cortes
Sent: Tuesday, September 08, 2009 11:56 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: NUCXDROP

Don't have one on either a 902 system or a 901 system.
No longer have any 801 systems to check.
The command still works though.


Marcy 

"This message may contain confidential and/or privileged information. If
you are not the addressee or authorized to receive this for the
addressee, you must not use, copy, disclose, or take any action based on
this message or any information herein. If you have received this
message in error, please advise the sender immediately by reply e-mail
and delete this message. Thank you for your cooperation."


-----Original Message-----
From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Jim Bohnsack
Sent: Tuesday, September 08, 2009 9:51 AM
To: IBMVM@LISTSERV.UARK.EDU
Subject: [IBMVM] NUCXDROP

I install maintenance, RSU 0902 at the moment, on a 2nd lvl system and
then move it to the test and production lpars.  When getting ready to
move CMS, I compare the 2nd lvl 190 disk with the old 190 disks on the
lpars.  On the 2nd lvl system with z/VM 5.4 at RSU0902, there is no
NUCXDROP MODULE.  It's on the test and production lpars running z/VM 5.4
at the level it was installed last fall, RSU0801, I guess.

Could someone else take a look if you've installed 0902 on z/VM 5.4 and
see if you've got it.  Did I just do a "whoops" with the maintenance?

Jim

--
Jim Bohnsack
Cornell University
(972) 596-6377 home/office
(972) 342-5823 cell
jab...@cornell.edu

_____________________________________________________
This message contains information which is privileged and confidential and is 
solely for the use of the
intended recipient. If you are not the intended recipient, be aware that any 
review, disclosure,
copying, distribution, or use of the contents of this message is strictly 
prohibited. If you have
received this in error, please destroy it immediately and notify us at 
privacy...@ailife.com.

Reply via email to