>From Operator
Q TERM

and see if the more 0 0 is in fact being set.

On Thu, Nov 11, 2010 at 3:55 PM, George Henke/NYLIC <
george_he...@newyorklife.com> wrote:

>
> Everything looks good except for 'MORE" processing.
>
> Although the OPERATOR screen does not got to "HOLD", it waits the default
> 50 seconds before scrolling to the next screen.
>
> It seems to be ignoring the  first  0 in TERM MORE 0 0
>
> Whether I use 2 TERM commands or 1 the result is the same.
>
> From OPERATOR's PROFILE EXEC:
>
> Address Command
> 'SYNONYM SYN'
> 'CP TERMINAL MODE VM'
> 'CP SPOOL CONSOLE * START'
> 'CP SET RUN ON'
> *'CP TERM HOLD OFF MORE 0 0'*
> 'CP SET PF11 RETRIEVE FORWARD'
> 'CP SET PF12 RETRIEVE BACKWARD'
> 'CP SET PF23 RETRIEVE FORWARD'
> 'CP SET PF24 RETRIEVE BACKWARD'
>
> Is the SET RUN ON perhaps interfering?
>
> It should be noted this is a PoC at Level 2
>
> Perhaps this difference in behavior is connected with that.
>
> Or is this how it is supposed to work?.
>
>
>
>  *Dave Jones <d...@vsoft-software.com>*
> Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
>
> 11/11/2010 11:09 AM
>  Please respond to
> The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
>
>   To
> IBMVM@LISTSERV.UARK.EDU
> cc
>   Subject
> Re: Streamlining the IPL
>
>
>
>
> Hi, George.
>
> To get CP to automatically IPL with no operator prompts for what kind of
> IPL to do and to set the date and time, add the following to the
> FEATURES statement in the production SYSTEM CONFIG file:
>
> ENABle AUTO_WARM_IPL,
>
>
> To have the TERM MORE 0 0 and TERM HOLD OFF commands automatically be
> issued at IPL time, you can either:
>
> 1) have the OPERATOR user id IPL CMS (with PARM AUTOCR specified) and
> then have the PROFILE EXEC file issue the CP TERM commands,
>
> or
>
> 2) add the COMMAND directory control statement to OPERATOR's user
> directory entry like so:
>
> COMMAND TERM MORE 0 0
> COMMAND TERM HOLD OFF
>
> if you do not want OPERATOR running CMS.
> Have a good one.
>
>
>
>
> On 11/11/2010 09:52 AM, George Henke/NYLIC wrote:
> >
> > ty, Kris and Alan, but what happens when the IPL prompts for Change
> > Date/Time?
> >
> > Can the prompt be surpressed?
> >
> > Also, what is the best way to issue the TERM command?
> >
> >
> >
> > *Kris Buelens <kris.buel...@gmail.com>*
> > Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
> >
> > 11/11/2010 10:47 AM
> > Please respond to
> > The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
> >
> >
> >
> > To
> >                  IBMVM@LISTSERV.UARK.EDU
> > cc
> >
> > Subject
> >                  Re: Streamlining the IPL
> >
> >
> >
> >
> >
> >
> >
> >
> > TERM HOLD OFF MORE 0 0
> >
> > 2010/11/11 George Henke/NYLIC < george_he...@newyorklife.com
> > <mailto:george_he...@newyorklife.com> >
> >
> > Is there a way to prevent the Level 1 operator console screen from
> > entering "MORE" or "HOLDING" state so that the IPL will continue
> > uninterupted by operator intervention?
> >
> > SET RUN ON will not.
> >
> >
> >
> > --
> > Kris Buelens,
> > IBM Belgium, VM customer support
>
> --
> Dave Jones
> V/Soft Software
> www.vsoft-software.com
> Houston, TX
> 281.578.7544
>  <george_he...@newyorklife.com>
>



-- 
Mark D Pace
Senior Systems Engineer
Mainline Information Systems

Reply via email to