On Wednesday, 01/05/2011 at 07:45 EST, Sergio Lima 
<sergiovm...@hotmail.com> wrote:

> As I learned in this list, I'm trying to use PIPE in some cases instead 
REXX.
> :
> Looking in the Manual CMS PIPELINES REFERENCE, Can't see how get the 
Return 
> Code.

While you are getting good answers from Kris and others, let me explain 
that there was no error in your pipe, so there is no non-zero RC.  The 
locate stage will send to its primary output stream all records that 
contain the string.  If no records contain the string, no records are sent 
to the primary output stream.

This is why Kris suggested counting the number of records in the primary 
output stream.

Alan Altmark

z/VM and Linux on System z Consultant
IBM System Lab Services and Training 
ibm.com/systems/services/labservices 
office: 607.429.3323
alan_altm...@us.ibm.com
IBM Endicott

Reply via email to