Frank:
You need another machine to check it, via SECUSER or OBSERVER enabled.
The "Operations Manager for zVM" product can monitor this condition.
Without the product, my first choice is "SET Observer" to PROP, and trap 
the "VM Ready" or "CP Ready" messages... 

PS. I don't see how AUDITOR works...
______________________________________________
Clovis



From:
"Frank M. Ramaekers" <framaek...@ailife.com>
To:
IBMVM@listserv.uark.edu
Date:
02/08/2011 13:13
Subject:
CMS Utilities AUDITOR and VMUTIL
Sent by:
The IBM z/VM Operating System <IBMVM@listserv.uark.edu>



I had an incident where VMUTIL abended, but AUDITOR didn’t detect it:
 
DMSFRO159E Insufficient storage available to satisfy free storage request 
from 01139EFE
DMSMOD109S Virtual storage capacity exceeded  
PIPCOM1296I ABEND in CMS command. Last 2 lines of output follow.   
PIPMSG003I ... Issued from stage 2 of pipeline 1.  
PIPMSG001I ... Running "CMS".  
PIPASY727I DMSLIO201W The following names are undefined:.  
PIPASY727I CEEEV003.  
  :
  :
 
The AUDITOR CONTROL file has:
 
************************************************************************
* AUDITOR CONTROL 
* CMS UTILITIES                                            @VRA8AWY 
************************************************************************
 
************************************************************************
* MACHINE     TEST    AUTO FORCE TEST     MAX   NOTIFY 
*   ID      INTERVAL  LOG  &AUTO EXIT     ERRS  USERID 
************************************************************************
  :
  :
 VMUTIL     00:05:00   1     1   NONE      10   MAINT 
 
Perhaps, I need a TEST EXIT, but I’m not sure how to test that VMUTIL is 
operating properly.
 
Ideas?
 

 Frank M. Ramaekers Jr.
 


Systems Programmer
MCP, MCP+I, MCSE & RHCE
 
American Income Life Insurance Co.
Phone: (254)761-6649
 
1200 Wooded Acres Dr.
Fax: (254)741-5777
 
Waco, Texas  76701
 
 
 
 
_____________________________________________________ This message 
contains information which is privileged and confidential and is solely 
for the use of the intended recipient. If you are not the intended 
recipient, be aware that any review, disclosure, copying, distribution, or 
use of the contents of this message is strictly prohibited. If you have 
received this in error, please destroy it immediately and notify us at 
privacy...@ailife.com. 


Reply via email to