Having said that, I've downloaded and applied the patches from github and have found a slightly annoying behaviour. Everytime I use the the buttons under the plotlist (both the orange ones and the purple ones) the component lists reset.
i.e. I set up a sum with component 1 as, say, HAuCl4 standard and component 2 as, say, Au foil and plot it. I then plot a couple of datasets using the buttons on the RHS. At this point all the component lists reset themselve to blank. I can reselect the component from the dropdown easily enough, but this is annoying if I have several components set up with corresponding weightings in a summation. Thanks, Ian -----Original Message----- From: Ifeffit [mailto:ifeffit-boun...@millenia.cars.aps.anl.gov] On Behalf Of Bruce Ravel Sent: 27 January 2016 14:33 To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov> Subject: Re: [Ifeffit] FW: Data summation - missing groups On 01/27/2016 06:33 AM, Godfrey, Ian wrote: > Sorry, I've just seen that this has already been reported. Indeed: http://millenia.cars.aps.anl.gov/pipermail/ifeffit/2015-November/008320.html This problem will be fixed whenever the next version of Demeter comes out. I apologize for the inconvenience in the meantime. B > Ian > > *From:*Godfrey, Ian > *Sent:* 27 January 2016 11:21 > *To:* 'XAFS Analysis using Ifeffit' > <ifeffit@millenia.cars.aps.anl.gov> > *Subject:* Data summation - missing groups > > Dear All, > > When using the data summation tool in Athena (0.9.24 x64 on Win10 Pro) > the first group in the group list seems to be missing from the > dropdown showing the potential components of a summation (see attached > screenshot). > > To reproduce: > > 1) Open attached project file and import with "select all" on the > import dialogue box > > 2) Change to data summation window > > 3) Try and add the first data group (234) to the summation from the > dropdown menus. (In the screenshot I've changed the default normmu(E) > to mu(E), but the same behaviour is displayed in both cases.) > > On a related note, I'm not sure I fully understand how the data > summation is different from the merge? Clearly data summation allows > you more control (arbitrary weighting of groups etc.) and is intended > for XANES analysis, but is it a fundamentally different procedure or > just a different interface for the same thing? > > Thanks, > > Ian > > Ian Godfrey > > PhD Student, > > UCL/JAIST Programme > > Industrial Doctorate Centre in Molecular Modelling and Materials > Science, > > Department of Chemistry, > > University College London, > > And > > School of Materials Science, > > Japan Advaned Institute of Science and Technology > > i.godf...@ucl.ac.uk <mailto:i.godf...@ucl.ac.uk> i.godf...@jaist.ac.jp > <mailto:i.godf...@jaist.ac.jp> > > 02076 794864 > > > > _______________________________________________ > Ifeffit mailing list > Ifeffit@millenia.cars.aps.anl.gov > http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit > Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit > -- Bruce Ravel ------------------------------------ bra...@bnl.gov National Institute of Standards and Technology Synchrotron Science Group at NSLS-II Building 535A Upton NY, 11973 Homepage: http://bruceravel.github.io/home/ Software: https://github.com/bruceravel Demeter: http://bruceravel.github.io/demeter/ _______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit _______________________________________________ Ifeffit mailing list Ifeffit@millenia.cars.aps.anl.gov http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit