Hi Bernie, This technique is indeed widely used in electronic microscopy, but Anastasiia (the author of the linked PhD thesis) used it on transmission optical microscopy. Her laboratory being on the same campus than mine I saw a seminar she gave during a local meeting. She showed very impressive pictures acquired on cells with a 5 or 10x on which she could zoom in (like Google Earth) and have a resolution similar to an acquisition with a 20 or 40x. I launched a colloboration with her on this project (she had the tool and we had the cells...) but than came the Covid confinment and everything was dead! By the time I visited her laboratory she was using a very cheap LED array bought at Amazon within the decoration categories. But they were planing to build a better quality setup but I don't know what was their last setup nor got the time to read her thesis. Take care, Philippe
----- Mail original ----- De: "Gluender" <[email protected]> À: "imagej" <[email protected]> Envoyé: Mercredi 3 Juin 2026 17:23:55 Objet: Re: ImageJ - Fungal hyphae thresholding Bonjour Philippe, I don't think this method is used in light-microscopy. The method is known since the late 1960s. Best Herbie ::::::::::::::::::::::::::::::::::::::::::::::::: Am 03.06.26 um 16:36 schrieb CARL Philippe (LBP): > Gruss Gott Herbie, > How are you doing ? > A technique which really impressed me is ptychographic microscopy: > https://theses.hal.science/tel-03636397v1 > Have you heard about it? > I was really impressed by the improvements given by this method and have to > admit that I didn't really understand the physics behind connected to the > Fourier space. > A really easy and cheap way to implement it is to acquire an array of LEDs > where you sequentially turn on a single LED and each time acquire a single > picture. > I guess you and Michael will really like to know about this technique in the > case it still isn't the case. > Kindest regards, > Philippe > > Philippe CARL > Laboratoire de Bioimagerie et Pathologies > UMR 7021 CNRS - Université de Strasbourg > Faculté de Pharmacie > 74 route du Rhin > 67401 ILLKIRCH > Tel : +33(0)3 68 85 41 41 > > ----- Mail original ----- > De: "Gluender" <[email protected]> > À: "imagej" <[email protected]> > Envoyé: Mardi 2 Juin 2026 13:35:05 > Objet: Re: ImageJ - Fungal hyphae thresholding > > You wrote: > > "[...] is there a tool that we can use to select only the fungal hyphae > of the emulsion surface?" > > A tool? > There may be methods / approaches to reduce the impact of image > artifacts and to more or less isolate the structures of interest but, as > mentioned before, without typical images, I see no way to provide > substantial help. > > Good luck > > Herbie > > ::::::::::::::::::::::::::::::::::::::::::::: > Am 02.06.26 um 14:26 schrieb Moraitou Themis: >> Thank you very much Herbie! >> >> Just one more question... >> Since our images have been taken using transmitted light, and the surface >> of a photographic slide is never absolutely clean (there are always surface >> deposits/dust, scratches etc), is there a tool that we can use to select >> only the fungal hyphae of the emulsion surface? >> >> Best >> Themis >> >> Στις Τρί 2 Ιουν 2026 στις 10:48 π.μ., ο/η Gluender <[email protected]> >> έγραψε: >> >>> Greetings Moraitou Themis! >>> >>> Without seeing typical images in their original non-lossy file-format >>> (no JPGs, no screen-shots) it is near to impossible to help. >>> >>> "What would be the best approach to improve the separation of hyphae from >>> the background before thresholding?" >>> >>> Frankly speaking: >>> The best pre-processing is no pre-processing but better images. >>> >>> You may try to improve image acquisition by using color lighting for >>> better contrast. Phase contrast may also be of some help. Avoid >>> "structures or artifacts are present in the image", etc. >>> >>> Best >>> >>> Herbie >>> >>> ::::::::::::::::::::::::::::::::::::::::::::: >>> Am 02.06.26 um 11:29 schrieb Moraitou Themis: >>>> Dear all, >>>> >>>> I am interested in quantifying fungal hyphae growth on the surface of >>>> photographic color slides using images taken with a Dino-Lite microscope. >>>> >>>> The basic workflow that I follow in ImageJ roughly includes: >>>> >>>> 1. Convert the image to 8-bit grayscale. >>>> 2. Apply Subtract Background. >>>> 3. Use automatic thresholding (Otsu and Li seem to give the best results >>> so >>>> far). >>>> >>>> However, I encounter two main issues: >>>> >>>> - The background is not uniform, and some structures or artifacts are >>>> present in the image. As a result, background subtraction is often not >>>> sufficient to isolate the hyphae. >>>> - In some regions, the contrast between the hyphae and the background is >>>> too low, so the threshold does not detect all hyphae consistently. >>>> >>>> What would be the best approach to improve the separation of hyphae from >>>> the background before thresholding? Are there specific preprocessing >>> steps, >>>> filters, color-space transformations, or segmentation methods in >>>> ImageJ/Fiji that could help achieve more reliable detection and >>>> quantification? >>>> >>>> Any suggestions or examples of similar workflows would be greatly >>>> appreciated. >>>> >>>> Thank you! >>>> >>>> -- >>>> ImageJ mailing list: http://imagej.nih.gov/ij/list.html >>>> >>> >>> -- >>> ImageJ mailing list: http://imagej.nih.gov/ij/list.html >>> >> >> > > -- > ImageJ mailing list: http://imagej.nih.gov/ij/list.html > > -- > ImageJ mailing list: http://imagej.nih.gov/ij/list.html > -- ImageJ mailing list: http://imagej.nih.gov/ij/list.html -- ImageJ mailing list: http://imagej.nih.gov/ij/list.html