https://issues.apache.org/jira/browse/CLOUDSTACK-9698?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15874500#comment-15874500
]
ASF GitHub Bot commented on CLOUDSTACK-9698:
--------------------------------------------
Github user borisstoyanov commented on the issue:
https://github.com/apache/cloudstack/pull/1861
@blueorangutan package
> Make the wait timeout for NIC adapter hotplug as configurable
> -------------------------------------------------------------
>
> Key: CLOUDSTACK-9698
> URL: https://issues.apache.org/jira/browse/CLOUDSTACK-9698
> Project: CloudStack
> Issue Type: Bug
> Security Level: Public(Anyone can view this level - this is the
> default.)
> Components: VMware
> Affects Versions: 4.9.0.1
> Environment: ACS 4.9 branch commit
> a0e36b73aebe43bfe6bec3ef8f53e8cb99ecbc32
> vSphere 5.5
> Reporter: Sateesh Chodapuneedi
> Assignee: Sateesh Chodapuneedi
> Fix For: 4.9.1.0
>
>
> Currently ACS waits for 15 seconds (*hard coded*) for hot-plugged NIC in VR
> to get detected by guest OS. The time taken to detect hot plugged NIC in
> guest OS depends on type of NIC adapter like (E1000, VMXNET3, E1000e etc.)
> and guest OS itself. In uncommon scenarios the NIC detection may take longer
> time than 15 seconds, in such cases NIC hotplug would be treated as failure
> which results in VPC tier configuration failure. Making the wait timeout for
> NIC adapter hotplug as configurable will be helpful for admins in such
> scenarios.
> Also in future if VMware introduces new NIC adapter types which may take time
> to get detected by guest OS, it is good to have flexibility of configuring
> the wait timeout.
--
This message was sent by Atlassian JIRA
(v6.3.15#6346)