Failover works fine on my 5800 cluster. I use direct connections for fabric and control. It sounds like you're losing traffic in Zmode. I'd start by taking a serious look at your fabric links. Do you have dual REs in each chassis for the double control links?
On Sep 3, 2013, at 7:34 AM, R S wrote: > We are having a geographic SRX5800 chassis cluster with two redundancy-groups > (RG0 and RG1). > > We are having many issues while performing the failover of the RG1, with and > without preemption. The issue is that when the RG1 becomes active on the > node1, real traffic is being lost. Also with preemption, when the node0 > becomes again the active for the RG1, lot of traffic is lost. > > There are dual Ctrl and Fabric link both through a Layer2 infrastructure, one > couple through MX960 and one couple through EX8200. > > Any similar nightmare ? > > Tks > _______________________________________________ > juniper-nsp mailing list juniper-nsp@puck.nether.net > https://puck.nether.net/mailman/listinfo/juniper-nsp _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp