Failover works fine on my 5800 cluster. I use direct connections for fabric and 
control.
It sounds like you're losing traffic in Zmode. I'd start by taking a serious 
look at your fabric links.
Do you have dual REs in each chassis for the double control links?


On Sep 3, 2013, at 7:34 AM, R S wrote:

> We are having a geographic SRX5800 chassis cluster with two redundancy-groups 
> (RG0 and RG1).
> 
> We are having many issues while performing the failover of the RG1, with and 
> without preemption. The issue is that when the RG1 becomes active on the 
> node1, real traffic is being lost. Also with preemption, when the node0 
> becomes again the active for the RG1, lot of traffic is lost.
> 
> There are dual Ctrl and Fabric link both through a Layer2 infrastructure, one 
> couple through MX960 and one couple through EX8200.
> 
> Any similar nightmare ?
> 
> Tks                                     
> _______________________________________________
> juniper-nsp mailing list juniper-nsp@puck.nether.net
> https://puck.nether.net/mailman/listinfo/juniper-nsp


_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to