Hi Alan, Thank you .. just what we needed.
Have a great day ! -----Original Message----- From: Linux on 390 Port [mailto:[EMAIL PROTECTED] On Behalf Of Alan Altmark Sent: Wednesday, September 19, 2007 10:59 AM To: LINUX-390@vm.marist.edu Subject: Re: channel bonding On Wednesday, 09/19/2007 at 10:47 EDT, "Ayer, Paul W" <[EMAIL PROTECTED]> wrote: > At this time in Vswitch only one OSA is really active and passing data. > > With (IEEE 802.3ad Link Aggregation) both OSA's would be moving data? With a z9 and z/VM 5.3, yes, you can have up to 8 OSAs moving data simultaneously for a single VSWITCH. (That's a theoretical maximum of 80Gb/s.) The physical switch is configured to bind the ports together into a single port group. Alan Altmark z/VM Development IBM Endicott ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390 ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390