Hi Alan,

Thank you .. just what we needed.

Have a great day !

-----Original Message-----
From: Linux on 390 Port [mailto:[EMAIL PROTECTED] On Behalf Of
Alan Altmark
Sent: Wednesday, September 19, 2007 10:59 AM
To: LINUX-390@vm.marist.edu
Subject: Re: channel bonding

On Wednesday, 09/19/2007 at 10:47 EDT, "Ayer, Paul W"
<[EMAIL PROTECTED]> wrote:

> At this time in Vswitch only one OSA is really active and passing
data.
>
> With (IEEE 802.3ad Link Aggregation) both OSA's would be moving data?

With a z9 and z/VM 5.3, yes, you can have up to 8 OSAs moving data
simultaneously for a single VSWITCH.  (That's a theoretical maximum of
80Gb/s.)

The physical switch is configured to bind the ports together into a
single
port group.

Alan Altmark