Got it!  Thanks for all the explanations.  Makes perfect sense when you think 
about it.

-----Original Message-----
From: Linux on 390 Port [mailto:LINUX-390@VM.MARIST.EDU] On Behalf Of Alan 
Altmark
Sent: Thursday, January 25, 2018 12:01 PM
To: LINUX-390@VM.MARIST.EDU
Subject: Re: [LINUX-390] Box confusion

On Thursday, 01/25/2018 at 07:38 GMT, Marcy Cortes 
<marcy.d.cor...@wellsfargo.com> wrote:
> Thanks!
>
> Shutdown -r did take them from a z13 to a z14 (no vm logoff).  Are you
saying
> it wouldn't downgrade them as well?

Yes, that's what I'm saying. 

CP won't fence an upgrade from a virtual machine.  If it doesn't use new 
facilities, no problem.  If it does, cool.  But in a downgrade scenario, you 
could lose instructions and die a horrible death, so it takes a virtual system 
reset to get CP to turn off the fence and let the downgrade through. 

Alan Altmark

Senior Managing z/VM and Linux Consultant IBM Systems Lab Services IBM Z 
Delivery Practice ibm.com/systems/services/labservices
office: 607.429.3323
mobile; 607.321.7556
alan_altm...@us.ibm.com
IBM Endicott

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions, send email to 
lists...@vm.marist.edu with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390
----------------------------------------------------------------------
For more information on Linux on System z, visit http://wiki.linuxvm.org/

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to lists...@vm.marist.edu with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390
----------------------------------------------------------------------
For more information on Linux on System z, visit
http://wiki.linuxvm.org/