Hi all, I've got a two node pacemaker/corosync cluster with some virtual domain resources on some DRBD devices. Every DRBD device is configured in dual primary setup and I have enabled the live migration. Cluster has also stonith enabled.
My problem is that if a live migration for a single virtualdomain resource fails, then this node gets fenced, making unavailable also all the other virtual machines (that gets restarted on the other node after a poweroff). As I saw the way to make a single resource fail not fencing the node where it fails is to declare an on-fail="restart" option for the virtual domain. Is it the correct approach or is there a more elegant way to obtain what I want? Thanks to all, -- RaSca Mia Mamma Usa Linux: Niente รจ impossibile da capire, se lo spieghi bene! ra...@miamammausalinux.org http://www.miamammausalinux.org _______________________________________________ Linux-HA mailing list Linux-HA@lists.linux-ha.org http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems