On Wed, Aug 16, 2017 at 04:14:50PM +0800, Dongjiu Geng wrote:
> The revision 0x300 generic error data entry is different
> from the old version, but currently iterating through the
> GHES estatus blocks does not take into account this difference.
> This will lead to failure to get the right data entry if GHES
> has revision 0x300 error data entry.
> 
> Update the GHES estatus iteration to properly increment using

                          iteration macro

> acpi_hest_get_next, and correct the iteration termination condition

Please end function names with parentheses.

> because the status block data length only includes error data length.

<---- newline here.

> Clear the CPER estatus printing iteration logic to use same macro.

s/Clear ... /Convert ... to the same macro./

> 
> Signed-off-by: Dongjiu Geng <[email protected]>
> CC: Tyler Baicar <[email protected]>
> ---
>  drivers/acpi/apei/apei-internal.h |  5 -----
>  drivers/firmware/efi/cper.c       | 12 ++----------
>  include/acpi/ghes.h               |  5 +++++
>  3 files changed, 7 insertions(+), 15 deletions(-)

With those addressed you can add:

Reviewed-by: Borislav Petkov <[email protected]>

-- 
Regards/Gruss,
    Boris.

SUSE Linux GmbH, GF: Felix Imendörffer, Jane Smithard, Graham Norton, HRB 21284 
(AG Nürnberg)
-- 