From: Ondrej Jirman <meg...@megous.com>

The current code defines W1 clock gate to be at 0x1cc, overlaying it
with the IR gate.

Clock gate for r-apb1-w1 is at 0x1ec. This fixes issues with IR receiver
causing interrupt floods on H6 (because interrupt flags can't be cleared,
due to IR module's bus being disabled).

Signed-off-by: Ondrej Jirman <meg...@megous.com>
Fixes: b7c7b05065aa77ae ("clk: sunxi-ng: add support for H6 PRCM CCU")
---
 drivers/clk/sunxi-ng/ccu-sun50i-h6-r.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/clk/sunxi-ng/ccu-sun50i-h6-r.c 
b/drivers/clk/sunxi-ng/ccu-sun50i-h6-r.c
index 27554eaf6929..8d05d4f1f8a1 100644
--- a/drivers/clk/sunxi-ng/ccu-sun50i-h6-r.c
+++ b/drivers/clk/sunxi-ng/ccu-sun50i-h6-r.c
@@ -104,7 +104,7 @@ static SUNXI_CCU_GATE(r_apb2_i2c_clk,       "r-apb2-i2c",   
"r-apb2",
 static SUNXI_CCU_GATE(r_apb1_ir_clk,   "r-apb1-ir",    "r-apb1",
                      0x1cc, BIT(0), 0);
 static SUNXI_CCU_GATE(r_apb1_w1_clk,   "r-apb1-w1",    "r-apb1",
-                     0x1cc, BIT(0), 0);
+                     0x1ec, BIT(0), 0);
 
 /* Information of IR(RX) mod clock is gathered from BSP source code */
 static const char * const r_mod0_default_parents[] = { "osc32k", "osc24M" };
-- 
2.21.0