Patrick McHardy wrote:
> Kok, Auke wrote:
>> Joonwoo Park wrote:
>>> IMHO even though netdevice is in the promiscuous mode, we should receive 
>>> all of ingress packets.
>>> This disable the vlan filtering feature when a vlan hw accel configured 
>>> e1000 device goes into promiscuous mode.
>>> This make packets visible to sniffers though it's not vlan id of itself.
>>> Any check, comments will be appreciated.
>> Actually I think this patch removes a choice from the user.
>>
>> Before this patch, the user can sniff all traffic by disabling vlans, or a
>> specific vlan only by leaving vlans on when going into promisc mode.
>>
>> After this patch, the user has no choice but to sniff all vlans at all times.
>>
>> I don't think that that is such a good improvement.
> 
> 
> Do you really consider that a realistic choice? Who is going to
> remove interfaces that are in use just to see traffic for other
> VLANs? Sniffing specific VLANs can always be done on the VLAN
> device itself.

right, I had not thought of that.

> IMO its more a question of what we want promiscous mode to mean,
> and I tend to agree with Joonwoo that it should receive all packets.

OK, Joonwoo: can you submit a patch against e1000e as well?

Auke
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to