Hi, On Wed, Jan 06, 2021 at 08:55:57AM +0100, Mike Looijmans wrote: > Add support for the LTC4162-L Li-Ion battery charger. The driver allows > reading back telemetry and to set some charging options like the input > current limit. > > Signed-off-by: Mike Looijmans <mike.looijm...@topic.nl> > --- > v2: Use microohm units instead of milliohm > Add interrupt support using smbalert > Support obtaining cell-count from devicetree > v3: Fix overflows in calculations involving resistor values > v4: Use attr_grp member to register attributes > Report input current/voltage for charger and make battery > voltage and current into sysfs attributes
Fine with me until we have a better way to solve the problem. IIUIC you no longer have access to the hardware anyways? But you need to document the custom sysfs nodes: Please document them in the following file: Documentation/ABI/testing/sysfs-class-power-ltc4162l [...] > +static int ltc4162l_remove(struct i2c_client *client) > +{ > + struct ltc4162l_info *info = i2c_get_clientdata(client); > + > + sysfs_remove_group(&info->charger->dev.kobj, <c4162l_attr_group); > + > + return 0; > +} power-supply core automatically removes the sysfs groups specified in power_supply_config.attr_grp. -- Sebastian