On Fri, Feb 12, 2021 at 03:06:42PM +0100, Bjarni Jonasson wrote:
> The current IB serdes calibration algorithm (performed by the onboard 8051)
> has proven to be unstable for the VSC8514 QSGMII phy.
> A new algorithm has been developed based on
> 'Frequency-offset Jittered-Injection' or 'FoJi' method which solves
> all known issues.  This patch disables the 8051 algorithm and
> replaces it with the new FoJi algorithm.
> The calibration is now performed in the driver.
> 
> Signed-off-by: Steen Hegelund <steen.hegel...@microchip.com>
> Signed-off-by: Bjarni Jonasson <bjarni.jonas...@microchip.com>
> Fixes: e4f9ba642f0b ("net: phy: mscc: add support for VSC8514 PHY.")
> ---

Tested-by: Vladimir Oltean <vladimir.olt...@nxp.com> # for regressions

Reply via email to