Hi Jacopo,
On Tue, Feb 16, 2021 at 6:41 PM Jacopo Mondi <[email protected]> wrote:
> The OV10640 image sensor reset and powerdown on signals are controlled
Drop the "on"?
> by the embedded OV490 ISP. The current reset procedure does not respect
> the 1 millisecond power-up delay and releases the reset signal before
> the powerdown one.
>
> Fix the OV10640 power up sequence by releasing the powerdown signal,
> waiting the mandatory 1 millisecond power up delay and then releasing
"powerdown" vs. "power-up" vs. "power up"?
> the reset signal. The reset delay is not characterized in the chip
> manual if not as "255 XVCLK + initialization". Wait for at least 3
> milliseconds to guarantee the SCCB bus is available.
Gr{oetje,eeting}s,
Geert
--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- [email protected]
In personal conversations with technical people, I call myself a hacker. But
when I'm talking to journalists I just say "programmer" or something like that.
-- Linus Torvalds