Hello, as far as i know, the endian typ on HP UX is big endian and on Linux it's little endian. Because of that a backup/restore copy from Windows to linux and vice versa is allowed, but from Linux to HPUX the endian type is different and therefore not allowed. Check SAP note 129352. You should copy your sapdb system with the migration tools. The handling of the endian typ on itanium is really funny. It depends on the os.
Best Regards -- Frank Weise SAP Certified Technical Consultant Collogia Unternehmensberatung AG Ubierring 11 50678 K�ln -- visit our website at http://www.collogia.de Zitat von "\"D�hr, Markus ICC-H\"" <[EMAIL PROTECTED]>: > We're trying to do some tests on a new Itanium-2 box, specifically we try to > compare performance between Linux_64 and HP-UX. We want to use a copy of our > production system to do some tests. > > Source: Linux_32/MaxDB 7.5.0 > > Target: Linux_64/MaxDB 7.5.0 works perfect > Target: HP-UX/MaxDB 7.5.0 does not work > > So is the endianess operating system dependent? What I don't get is that on > the same box Linux_64 works but HP-UX does not. > > Could someone please clarify? > > > Thank you! > > > Greetz, > > > SIEGENIA-AUBI KG > Informationswesen > > i.A. > > Markus D�hr > SAP-CC/BC, SAPDB-DBA > > Tel.: +49 6503 917-152 > Fax: +49 6503 917-7152 > E-Mail: [EMAIL PROTECTED] > Internet: http://www.siegenia-aubi.com > > > -- > MaxDB Discussion Mailing List > For list archives: http://lists.mysql.com/maxdb > To unsubscribe: http://lists.mysql.com/[EMAIL PROTECTED] > > > -- MaxDB Discussion Mailing List For list archives: http://lists.mysql.com/maxdb To unsubscribe: http://lists.mysql.com/[EMAIL PROTECTED]
