David W. Tamkin said:
> A sampling rate converter has to interpolate values between samples to gene-
>rate [a model of] a continuous waveform just as a DAC does, and then it has
>to sample that [model of a] waveform just as an ADC does
This is true; both SRC and DAC/ADC methods accomplish the same end. The
big difference is that the SRC uses numerical methods, which when done properly,
introduces much less noise and distortion than the DAC/ADC method. It is much
harder to eliminate noise and non-monotonicity in DAC/ADC than it is to get
sufficient DSP speed for good SRC algorithms.
-----------------------------------------------------------------