On Tue, 23 Feb 2021 11:29:00 +0100, Stefan Sperling wrote:

> I've noticed a similar effect on a slower link (VDSL with 50 down/ 10 up).
> In this case the VDSL modem presents an Ethernet switch, so there is no
> pppoe or vlan involved in the box that runs pf.
>
> As soon as I enable this example given in pf.conf(5):
>
>        queue outq on em0 bandwidth 9M max 9M flows 1024 qlimit 1024 \
>              default
>
> I see only about 2 or 3 Mbit/s max upload during tcpbench.
> Which is indeed quite a hit compared to 10M.

That's odd.  I haven't had any problems with a VDSL connection with
100 down / 11 up.  My config is very similar to yours:

queue outq on em2 flows 1024 bandwidth 10M max 10M qlimit 1024 default

where em2 the underlying interface used by pppoe0.  Without queueing
I have major problems when utilizing the upstream bandwidth, probably
due to dropped ACKs.

 - todd