On Thu, 2009-09-10 at 09:16 -0400, NAP wrote: > I cant get value in this OID. This is on ciso catalyts 6509 (IOS Version > 12.2(33)SXH4) > > snmpget -v 2c -c napgate 200.0.16.126 1.3.6.1.4.1.9.9.13.1.3.1.3.1 > SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1 = No Such Instance currently > exists at this OID >
when running modularity code, the instance number is not 1. Try walking 1.3.6.1.4.1.9.9.13.1.3.1.3 Nor do the instance numbers line up with the entity-mib values. > -- Daniel J McDonald, CCIE # 2495, CISSP # 78281, CNX www.austinenergy.com
signature.asc
Description: This is a digitally signed message part
_______________________________________________ mrtg mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg