Hi,

I'm looking at the Verizon NEBS requirements, which along with GR-63 and
GR-1089 call out the design guidelines in GR-78. Does GR-78 compliance have
to be assessed independently for Verizon compliance, or is manufacturer's
declaration on the NEBS checklist sufficient (section 2.8.1 would suggest
otherwise, but design guidelines are not as readily measurable as say,
environmental or EMC criteria)?

Also, has anyone out there put together a fire resistance database in
accordance with GR-63 4.3.2.1 before? Was it necessary for Verizon
compliance? Or is shelf/frame-level flame testing and needle-flame component
testing sufficient, provided the split-frame infra-red video requirements
for Verizon are met?

Thanks in advance,

Dave Wilson
Manager, Quality & Compliance
Alidian Networks, Inc.