On 25/04/07, Lambert, Eric <[EMAIL PROTECTED]> wrote:
> Apr 25 15:19:44 lx-chtdell2950 snmpd[14938]: trigger OID: =
> Apr 25 15:19:44 lx-chtdell2950 snmpd[14938]: /etc/snmp/snmpd.conf: line
> 99: Error: unknown monitor OID
> Apr 25 15:19:44 lx-chtdell2950 snmpd[14938]: net-snmp: 1 error(s) in
> config file(s)


Just a guess, but try:

   a)  with numeric instance subidentifiers
              (nsExternalResult.12.115.119.97.112.95.112.101.114.99.101.110.116)
   b)  escaping the double quotes
              (nsExternalResult.\"swap_percent\")
   c)  monitoring the MIB object (nsExternalResult) rather than an instance.

Dave

-------------------------------------------------------------------------
This SF.net email is sponsored by DB2 Express
Download DB2 Express C - the FREE version of DB2 express and take
control of your XML. No limits. Just data. Click to get it now.
http://sourceforge.net/powerbar/db2/
_______________________________________________
Net-snmp-users mailing list
Net-snmp-users@lists.sourceforge.net
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users

Reply via email to