Hi to all, I still have problem with my 1wire bus.
I get from bus.0/statistics/errors CRC16_errors 0 CRC16_tries 20971 CRC8_errors 81 CRC8_tries 88760 bus.0/statistics/return_codes/responses.0 358105 bus.0/statistics/return_codes/responses.27 41 bus.0/bus.0/interface/statistics/search_errors (13 Clients) error_pass_1 0 error_pass_2 0 error_pass_3 0 bus.0/bus.1/interface/statistics/search_errors (11 Clients) error_pass_1 0 error_pass_2 0 error_pass_3 0 bus.0/bus.2/interface/statistics/search_errors/ (9 Clients) error_pass_1 26 error_pass_2 5 error_pass_3 1 bus.0/bus.3/interface/statistics/search_errors/ (5 Clients) error_pass_1 0 error_pass_2 0 error_pass_3 0 How do I have to see these Error Counters ? This is the device list 10.2249AD020800 10.2249AD020800 directory 10.362EAB020800 10.362EAB020800 directory 28.41A5B5040000 28.41A5B5040000 directory 3A.02B307000000 3A.02B307000000 directory 26.682D71010000 26.682D71010000 directory 26.58F59B010000 26.58F59B010000 directory 26.EB009B010000 26.EB009B010000 directory 29.A20000000001 29.A20000000001 directory <--- Atmel (Software Client) 29.A30000000001 29.A30000000001 directory <--- Atmel (Software Client) But the Problem is with or/without the Atmel Clients existing. Do I have the chance to see, which "1-wire Partner" has/makes the problem. Up to now, I just check the values above. I already checked connections, voltage and cabling, more than once. Depending on which 1-wire clients I have connected, I suddenly see some devices double or triple in device list. I removed all clients and check the cabling, no short cut seen so far. I removed all shield's of cabling at the end of the cable and now I have a ripple voltage smaller than 5mV and constant a 5.17 Votage supply. Almost all 1-wire client are using a BAT54S to reduce noise of the 1-wire signal. Next step, I would like to use a laboratory power supplies, to see the use current and regulation. I noticed, that almost the DS2438 makes me problems, because of the VDD and the VAD Value. Sometimes the VDD value is below 3 Volt and the VDA show 5.17 (swapped or have the same value). But the Oszilloscope does not show any problems (but maybe really short spikes I can not see). I am using the offical 2.8p15 Version of the standard debian installation. Is this a known problem of the version 2.8p15 or still related to a hardware problem. I could not see any related entry in the offical change log of the owserver, which was telling something in this matter. I am pleased about every hint to get closer or fix this problem. Best regards Ritchie ------------------------------------------------------------------------------ BPM Camp - Free Virtual Workshop May 6th at 10am PDT/1PM EDT Develop your own process in accordance with the BPMN 2 standard Learn Process modeling best practices with Bonita BPM through live exercises http://www.bonitasoft.com/be-part-of-it/events/bpm-camp-virtual- event?utm_ source=Sourceforge_BPM_Camp_5_6_15&utm_medium=email&utm_campaign=VA_SF _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers