At my lab i have only one sensor - DS18B20 The Raspberry has standard kernel driver for 1w interface. And it has mounted folder /sys/bus/w1/devices where i can also read temperature value. Directly from file (for ex. /sys/bus/w1/devices/28-000005de7fdc/w1_slave)
Today (24h) with script I tested reading temperature directly from file and from requests of owserver every minute. at first where is no one error, from owserver 1 of 10 requests - i have UNDEFINE value now i think to modify openhab config to migrate from owserver technology to simple reading from file. -- View this message in context: http://owfs-developers.1086194.n5.nabble.com/some-problem-with-owserver-tp11288p11296.html Sent from the OWFS Developers mailing list archive at Nabble.com. ------------------------------------------------------------------------------ BPM Camp - Free Virtual Workshop May 6th at 10am PDT/1PM EDT Develop your own process in accordance with the BPMN 2 standard Learn Process modeling best practices with Bonita BPM through live exercises http://www.bonitasoft.com/be-part-of-it/events/bpm-camp-virtual- event?utm_ source=Sourceforge_BPM_Camp_5_6_15&utm_medium=email&utm_campaign=VA_SF _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers