Hi Brad,

Okay looks like it has been resolved. I checked in Preferences and the x,y 
co-ordinates for both fields was set way off somewhere ie no 0,0. I have neve 
worried about this in the past because I assumed (idiot) that the Auto-place of 
Centre-Above and Centre-Below would override everything. This it does when you 
apply a change to some parameter for the item but only if it is not hidden. Now 
with this set to 0,0 for both fields, my components are placing with the fields 
close to the part (slap bang in the middle to be precise) although I still have 
to kick the part to get the Auto-place function to take over.

I recall a thread awhile ago related to `parts' being off the page or even out 
of reach and I can easily imagine that if I place one of my older parts near 
the edge of a worksheet that I would `lose' at least one of the fields. Doing a 
global Auto-place with the fields NOT hidden has been the only way to bring 
everything back in to `scope'

Thanks for the feedback (and everyone else who responded) looks like I will be 
working with Protel 99SE for a bit longer (although my work situation is about 
to force a leap to Altium Designer now - doh)

Best Regards

(Mr) Laurie Biddulph
Mobile: 0404 846 943

Elby Designs
ABN: 70 022 727 605
http://www.elby-designs.com

This e-mail and any files transmitted with it are confidential and intended for 
the addressee only.
If you are not the addressee you may not copy, forward, disclose or otherwise 
use it, or any part
of it, in any form whatsoever. If you have received this e-mail in error please 
notify the sender
and ensure that all copies of this e-mail and any files transmitted with it are 
deleted. Any views
or opinions represented in this e-mail are solely those of the author and do 
not necessarily
represent those of Elby Designs. Although this e-mail and its attachments have 
been scanned for the
presence of computer viruses, Elby Designs will not be liable for any losses as 
a result of any
viruses being passed on.

  ----- Original Message ----- 
  From: Brad Velander 
  To: Protel EDA Discussion List 
  Sent: Tuesday, October 25, 2005 1:37 AM
  Subject: RE: [PEDA] Protel 99SE Footprints


  Laurie,
  I have never seen that problem with any library parts I have created. I would 
suggest that you look at the following. Where are your parts located with 
respect to 0,0 in the library? Do you have some small line, text or other item 
way off away from the part? The designators will locate themselves relative to 
the extents of your footprint.

  Sincerely,
  Brad Velander
  Senior PCB Designer
  Northern Airborne Technology
  #14 - 1925 Kirschner Road,
  Kelowna, BC, V1Y 4N7.
  tel (250) 763-2329 ext. 225
  fax (250) 762-3374



  -----Original Message-----
  From: Laurie Biddulph [mailto:[EMAIL PROTECTED]
  Sent: Saturday, October 22, 2005 2:36 PM
  To: [email protected]
  Subject: [PEDA] Protel 99SE Footprints


  I have created a number of component footprints for my pcb designs (Protel 
99SE). When placing these components the Designator and Part Type fields are 
always a long way off from the component unlike the footprints that were 
supplied with Protel. What do I need to do to the footprint to force these 
fields to start initially next to the footprint?

  I know that, once applied, I can reposition using the `position field' (which 
by the way already defaults to Centre-Above and Centre-Below) but this has to 
be done with EVERY homemade footprint I have created.

  Best Regards

  (Mr) Laurie Biddulph
  Mobile: 0404 846 943

  Elby Designs
  ABN: 70 022 727 605
  http://www.elby-designs.com
   

   
  ____________________________________________________________
  You are subscribed to the PEDA discussion forum

  To Post messages:
  mailto:[email protected]

  Unsubscribe and Other Options:
  http://techservinc.com/mailman/listinfo/peda_techservinc.com

  Browse or Search Old Archives (2001-2004):
  http://www.mail-archive.com/[email protected]
   
  Browse or Search Current Archives (2004-Current):
  http://www.mail-archive.com/[email protected]

____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]

Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to