[EMAIL PROTECTED] wrote:

>Hello out there,
>
>I have the following problem: When I changed something within my schematic - 
>e.g. using another pin-compatible memory-IC - there are many tracks in my 
>layout, who's netnames got lost.
>
>So: If I mount the new (pin-compatible) IC to the same position (and 
>orientation), all those old connection could be recycled. But I receive many 
>DRC-errors, because of the lost netnames. Of course I could assign the correct 
>netnames to the tracks, but this is more work than placing the tracks again.
>
>Is it possible to re-assign only one track's correct netname and let protel 
>assign the same netname to all tracks, vias, etc. that have a 'physical' 
>connection to the initial-track? 
>
>So that the re-assigned netname 'pours' through my layout...?
>
>I work with protel 99SE SP6
>
>Have a nice weekend!
>
>Kind regards
>Christian
>
> 
>____________________________________________________________
>You are subscribed to the PEDA discussion forum
>
>To Post messages:
>mailto:[email protected]
>
>Unsubscribe and Other Options:
>http://techservinc.com/mailman/listinfo/peda_techservinc.com
>
>Browse or Search Old Archives (2001-2004):
>http://www.mail-archive.com/[email protected]
> 
>Browse or Search Current Archives (2004-Current):
>http://www.mail-archive.com/[email protected]
>
>  
>
Christian,

It appears you need to "update free primitives from compomemt pads".
Go To Design, Netlist Manager, Menu and select "update free primitives 
from compomemt pads".

Regards,

Jim McGrath

 
____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
 
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to