On Thu, Jun 9, 2011 at 12:36 AM, Martin Dias <[email protected]> wrote:
> > On Wed, Jun 8, 2011 at 10:35 PM, Eliot Miranda <[email protected]>wrote: > >> Hi Martin and Mariano, >> >> a couple of questions. What's the right way to exclude certain >> objects from the serialization? Is there a way of excluding certain inst >> vars from certain objects? >> >> > Hi, > > We are close to have this feature, but still is an open issue. > > The idea is to to support this "statically" via: > > ClassWithTransients >> fuelTransientInstanceVariables > ^ #(myTransientValue1 myTransientValue1) > > or more dinamically via: > > FLSerializationSettings newDefault > onClass: ClassWithTransients > declareTransients: #(myTransientValue1 myTransientValue1). > > Do you have a better idea? > No. The above looks fine. > > Cheers > Martin > > > >> best >> Eliot >> > >