On Thu, Jun 9, 2011 at 12:36 AM, Martin Dias <[email protected]> wrote:

>
> On Wed, Jun 8, 2011 at 10:35 PM, Eliot Miranda <[email protected]>wrote:
>
>> Hi Martin and Mariano,
>>
>>     a couple of questions.  What's the right way to exclude certain
>> objects from the serialization?  Is there a way of excluding certain inst
>> vars from certain objects?
>>
>>
> Hi,
>
> We are close to have this feature, but still is an open issue.
>
> The idea is to to support this "statically" via:
>
> ClassWithTransients >> fuelTransientInstanceVariables
>    ^ #(myTransientValue1 myTransientValue1)
>
> or more dinamically via:
>
> FLSerializationSettings newDefault
>     onClass: ClassWithTransients
>     declareTransients: #(myTransientValue1 myTransientValue1).
>
> Do you have a better idea?
>

No.  The above looks fine.


>
> Cheers
> Martin
>
>
>
>> best
>> Eliot
>>
>
>

Reply via email to