--- On Mon, 8/20/12, Wietse Venema <[email protected]> wrote:

> From: Wietse Venema <[email protected]>
> Subject: Re: How to correctly signal postfix to close the session from an TCP 
> Table/Policy Service - Connections are kept open for 1min after service 
> shutdown
> To: "Postfix users" <[email protected]>
> Date: Monday, August 20, 2012, 9:17 AM
> The tcp_table client timeout is not
> configurable (it also is not
> 60s).  Closing the socket after each query is wrong.
> 
> First, you need to set the SO_REUSEADDR socket option on the
> LISTEN
> socket.

This did the trick, thank you!

> 
> Second, before restarting your server, you need to terminate
> ALL
> tcp table server processes.

I did that already, but the issue is now resolved - thanks!

Reply via email to