--- In [email protected], "quantiworks" <[EMAIL PROTECTED]> wrote:
>
> commands
> Start|Stop|<RESET>|
This is confusing. Are you saying you entered the same thing for all
three?
FWIW, here's what I currently have:
=================================
Timer a
Checkmark "Down", zeros for all the numbers
Start command: (none)
Stop command: (none)
Reset command: ;
More commands:
Global lockvar=messagebox("YesNo Question", "Ready for a Break?", "RSI
Awareness" )
*Script If (lockvar==6) do
*Shutdown LockWorkStation noconfirm
*Timer Set + a 0 30 0
else
*Timer Set + a 0 5 0
endif
====================================
Timer b
Checkmark "Down", Checkmark "Auto Start", 1 minute Reset Time
Reset command: ;
More commands:
*Script If (win.getdesktopname=="")
*Timer Set +a 0 30 0
=====================================
Scheduled Event
Checkmark "Startup"
*Timer Set +a 0 30 0
=====================================
Bar button:
Label: *Info RSI Countdown: timersec a
Tooltip: Timer/ Lft-click Add 30 min/Mid-click RSI Now/Set to 30 min
Left Command: *Timer Set +@ a 0 5 0
Middle Command: *Timer Set + a 0 0 0
Right Command: *Timer Set + a 0 30
=====================================