We have used TeleView many times with multiple dosimeters but it was all done manually. It was done during diving operations so we were not connected to the network. We do not use Sentinel, but HIS-20 but if the information is stored on the tables in your database it should be able to be added to the view.
TeleView worked fine with multiple dosimeters in the local mode we used it in. From: [email protected] [mailto:[email protected]] On Behalf Of Bradley A Krupp Sent: Tuesday, August 26, 2014 1:30 PM To: [email protected] Subject: Powernet: Sentinel and TeleView Fermi would like feedback from peers using Sentinel for RRA Access Control and TeleView 2000 for telemetry monitoring. TeleView periodically queries a view on our Sentinel server and matches up transmitting Electronic Dosimeters with an individual and displays their name and other information in a container. Right now we can only retrieve data for individuals who are wearing a single transmitting dosimeter. We are evaluating using the multipack management application in Sentinel and would like to be able to retrieve information (RWP, Task, name, etc.) on all transmitting dosimeters an individual may be wearing. This would be done at the same time as individuals who have logged in with transmitting dosimeters using the normal RCA Access application. Does anyone have this capability using these applications? If so, what did you need to do to make it work? Thanks in advance for your assistance. Brad Krupp