Create a “View” in ORACLE with the fields you want the data to be displayed in 
Teleview.  Populate the “view” with the specific fields from the Sentinel 
multipack management application where the individual dosimeters are assigned 
to specific locations.  You can age the RWP data and setpoints from Sentinel 
tables also to add to the VIEW.  By populating the VIEW table the Teleview 
interface only needs to get data from this one “view” or table, thus increasing 
speed, accuracy and efficiency.  Your IT database contact should be able to do 
this easily.  Your testing will have to make sure you have used the correct 
multibadge tables for obtaining the data and that the table “view” is cleared 
when a person logs out. 

 

From: [email protected] [mailto:[email protected]] On Behalf Of 
Bradley A Krupp
Sent: Tuesday, August 26, 2014 2:30 PM
To: [email protected]
Subject: Powernet: Sentinel and TeleView

 

Fermi would like feedback from peers using Sentinel for RRA Access Control and 
TeleView 2000 for telemetry monitoring.  TeleView periodically queries a view 
on our Sentinel server and matches up transmitting Electronic Dosimeters with 
an individual and displays their name and other information in a container.  
Right now we can only retrieve data for individuals who are wearing a single 
transmitting dosimeter.  We are evaluating using the multipack management 
application in Sentinel and would like to be able to retrieve information (RWP, 
Task, name, etc.) on all transmitting dosimeters an individual may be wearing.  
This would be done at the same time as individuals who have logged in with 
transmitting dosimeters using the normal RCA Access application.  Does anyone 
have this capability using these applications?  If so, what did you need to do 
to make it work?  Thanks in advance for your assistance.

 

Brad Krupp

 

Reply via email to