Gary,

from your logfile (at each packet, at each build stage):

bash: AR=i586-pmmx-linux-gnu-ar AS=i586-pmmx-linux-gnu-as 
CXX=i586-pmmx-linux-gnu-g++ CC=i586-pmmx-linux-gnu-gcc CC_FOR_BUILD=gcc 
CPP_FOR_BUILD=gcc LINK_FOR_BUILD=gcc LD=i586-pmmx-linux-gnu-ld 
NM=i586-pmmx-linux-gnu-nm OBJCOPY=i586-pmmx-linux-gnu-objcopy 
OBJDUMP=i586-pmmx-linux-gnu-objdump RANLIB=i586-pmmx-linux-gnu-ranlib 
READELF=i586-pmmx-linux-gnu-readelf STRIP=i586-pmmx-linux-gnu-strip 
DLLTOOL=i586-pmmx-linux-gnu-dlltool  
CPPFLAGS='-isystem /home/gthomas/test_i386/local/i586-pmmx-linux-gnu/include 
-isystem /home/gthomas/test_i386/local/i586-pmmx-linux-gnu/usr/include' 
LDFLAGS='-L/home/gthomas/test_i386/local/i586-pmmx-linux-gnu/lib 
-L/home/gthomas/test_i386/local/i586-pmmx-linux-gnu/usr/lib -Wl,-rpath-link 
-Wl,/home/gthomas/test_i386/local/i586-pmmx-linux-gnu/usr/lib' 
CXXFLAGS='-isystem /home/gthomas/test_i386/local/i586-pmmx-linux-gnu/include 
-isystem /home/gthomas/test_i386/local/i586-pmmx-linux-gnu/usr/include' 
SYSROOT=/home/gthomas/test_i386/local/i586-pmmx-linux-gnu 
PKG_CONFIG="/home/gthomas/test_i386/local-cross/bin/i586-pmmx-linux-gnu-pkg-config"
 
ac_cv_sizeof_long_long=8 ac_cv_sizeof_long_double=8 
ac_cv_func_getpgrp_void=yes ac_cv_func_setpgrp_void=yes 
ac_cv_func_memcmp_clean=yes ac_cv_func_setvbuf_reversed=no 
ac_cv_func_getrlimit=yes ac_cv_type_uintptr_t=yes 
ac_cv_func_posix_getpwuid_r=yes ac_cv_func_dcgettext=yes 
gt_cv_func_gettext_libintl=yes ac_cv_sysv_ipc=yes 
DESTDIR=/home/gthomas/test_i386/local/i586-pmmx-linux-gnu 
ac_cv_func_setvbuf_reversed=no bash_cv_have_mbstate_t=yes: File name too long
                                                           ^^^^^^^^^^^^^^^^^^
Did you recognize the "File name too long"? You bash seems to have a problem 
with the environment size.

The rest of this line is similar to mine. Only the bash error is not present 
in my build.

Juergen
-- 
Dipl.-Ing. Juergen Beisert | http://www.pengutronix.de
 Pengutronix - Linux Solutions for Science and Industry
    Handelsregister: Amtsgericht Hildesheim, HRA 2686
         Vertretung Sued/Muenchen, Germany
   Phone: +49-8766-939 228 |  Fax: +49-5121-206917-9

-- 
ptxdist mailing list
[email protected]

Reply via email to