I can only acknowledge this. Speed went down as the cache tier went full. Even 
with superfast PCIe SSDs.

Additionally i think it is error prone.
I ran into the problem, that a ssd stuck because it was full causing the 
complete storage to stuck.
There is a parameter for the maximum size of the cache, but it does not prevent 
a single ssd in the cache-tier to be filled completely - at least i didn't find 
any method despite of the balance factor for the osds, but that didn't help.
I my setup there were 3 SSDs for caching.
One of them went full, even when the sum of the used storage was smaller than 
the maximum cache size.

Kind Regards

Valentin
________________________________________
Von: pve-user [pve-user-boun...@pve.proxmox.com]" im Auftrag von 
"Lindsay Mathieson [lindsay.mathie...@gmail.com]
Gesendet: Sonntag, 9. Oktober 2016 00:21
An: PVE User List
Betreff: Re: [PVE-User] Ceph Cache Tiering

On 9/10/2016 7:45 AM, Lindsay Mathieson wrote:
> cache tiering was limited and a poor fit for VM Hosting, generally the
> performance was with it

"was *worse* with it"


:)

--
Lindsay Mathieson

_______________________________________________
pve-user mailing list
pve-user@pve.proxmox.com
http://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-user