Good evening everyone, wouldn’t you just know it, six months of inactivity then 
when I want to run the Q it starts to act up. I set off from home and within 
400m it cut out, the fuel pump not running, the fuses etc were ok, so I changed 
the fuel pump relay for a known good spare, still nothing, when I could finally 
find the access cover to the tank I found there was no power at the plug, I 
checked and tested what I could then ran a fly lead from power , cut into the 
supply wire at the plug on the tank, connected the fly lead and the pump ran. 
Does anyone know where, if fitted the inertia cut off would be fitted before I 
splice in a new supply, stoneleigh isn’t far away. Many thanks.
Bill

Sent from my iPhone

-- 
-- 
You received this message because you are subscribed to the Google Groups 
"Quantum Owners Group" group.
To post to this group, send email to quantumowners@googlegroups.com
To unsubscribe from this group, send email to 
quantumowners-unsubscr...@googlegroups.com
For more options, visit this group at 
http://groups.google.com/group/quantumowners?hl=en

IMPORTANT NOTE: All information presented herewith is provided on an "As Is" 
basis, without warranty or the implication thereof. Neither the Quantum Owners 
Club nor the individuals associated with the Quantum Owners Club or in the 
preparation of the above information shall have any liability to any person or 
entity with respect to liability, loss, or damage caused or alleged to be 
caused directly or indirectly by the instructions contained within this or 
related message(s).
--- 
You received this message because you are subscribed to the Google Groups 
"Quantum Owners Group" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to quantumowners+unsubscr...@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to