Does anyone know the trick to make the XG3 send its CW buffer memory. I use
the tool to configure it:
WM,de_w6das_test;
I do WM;
unit responds with WM WM,de_w6das_test;
According to instructions, this confirms the CW buffer is programmed.
If I do W;
Unit is supposed to send the CW buffer
Hi Dan,
The 'W' command does not send the CW memory, it sends any text following the
'W' command. For example: W,de_n6hz; would send 'de n6hz' in CW
immediately. To send the CW memory you have to first set the programmable
PF1 key (BAND+) to function as the Morse memory sender (normally it
Paul,
I did the PF,01,01; command. It changed the function of holding the PF1
button from sending the sweep sequence to sending a steady carrier on the
original frequency for which the 20M band was configured on the XG3. I then
did PF,01,00; which restored the sweep function. What I had before