Re: [Sip-implementors] SIP REGISTER MESSAGE flow

2021-11-20 Thread Arun Tagare
Thanks Ranjit & Paul, Yes, NW can send ‘n’ number of PCSCF addresses, Yes, agree Ranjit it’s may be not practical but just wanted to understand if that is allowed? Or Nw accepts REG in sequence like Reg to 1 PCSCF Fail/error response from NW Then retry on 2PCSCF address Fail/error response from

Re: [Sip-implementors] SIP REGISTER MESSAGE flow

2021-11-20 Thread Ranjit Avasarala
Hi Arun I am not sure how you can get more than 1 P-CSCF address(s) as the P-CSCF address is discovered by UE i.e returned by GGSN. So even if we assume a scenario where the GGSN returns 5 P-CSCF address, then yes u can send REGISTER to all of them ( but this is not a practical scenario) Then as

Re: [Sip-implementors] SIP REGISTER MESSAGE flow

2021-11-20 Thread Paul Kyzivat
Arun, Your query doesn't have enough context to understand the case. It does however appear to more likely to be something that should be answered by someone in the 3GPP IMS community. If you want an answer here please spell out your case in much more detail. Thanks, Paul On