Re: Latency on the local access circuit [7:26263]

2001-11-15 Thread Dude

Has anyone got any information/links on how to configure a window2000 cert
server to enroll a pix??  The TAC is informative enough about the pix side
of things and offers a decent link to the MS site, but there is no mention
that I can find of how to create a CEP compatible certificate for the pix...

any help much appreciated.

thanks,
Ciaron

- Original Message -
From: Paul Jin 
To: 
Sent: Thursday, November 15, 2001 8:47 PM
Subject: Re: Latency on the local access circuit [7:26263]


> VoIP Guy wrote:
> >
> > If traffic shaping, do both sides match?Are you doing any
> > FRF.12
> > fragmentation?   Are you sure the traffic shaping paramaters
> > are OK?  I have
> > a feeling this is it.  Make sure both sides match.
> >
> >
>
> The TS statements both match on both ends.
>
> We have the same type of PVC with same CIR and other parameters
> going to other sites and using the same TS configuration.
>
> And no frame fragmentations.
>
> I do have it schduled to swap this router out
> within 2 weeks.  I am hoping it is either the router or
> the local cabling to the router.
>
> We could not get the regular 1720 that we wanted to deploy until Dec so we
> have a temp 2501 that the local field company used and I do not know how
> steady this router is.
>
> thanks
> Paul




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26421&t=26263
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: Latency on the local access circuit [7:26263]

2001-11-15 Thread Paul Jin

VoIP Guy wrote:
> 
> If traffic shaping, do both sides match?Are you doing any
> FRF.12
> fragmentation?   Are you sure the traffic shaping paramaters
> are OK?  I have
> a feeling this is it.  Make sure both sides match.
> 
> 

The TS statements both match on both ends. 

We have the same type of PVC with same CIR and other parameters
going to other sites and using the same TS configuration.

And no frame fragmentations.  

I do have it schduled to swap this router out
within 2 weeks.  I am hoping it is either the router or
the local cabling to the router.

We could not get the regular 1720 that we wanted to deploy until Dec so we
have a temp 2501 that the local field company used and I do not know how
steady this router is.

thanks
Paul


Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26413&t=26263
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



Re: Latency on the local access circuit [7:26263]

2001-11-14 Thread VoIP Guy

If traffic shaping, do both sides match?Are you doing any FRF.12
fragmentation?   Are you sure the traffic shaping paramaters are OK?  I have
a feeling this is it.  Make sure both sides match.


""Paul Jin""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hi Alex,
>
> This site has another router connection back to the hub so this PVC is not
> being used at this moment except for testing.
>
> I have no fecn/becns.  I have the CIR set at 128K on the network portion.
>
> No discards within the cloud.  in fact, within the network, it is
> around 70 ms between stratacom to stratacom.  But between the router
> to router ping, it is very abnormally high.
>
> The hub site has other PVCs exiting to other routers and they all
> work ok.  Just this particular one.
>
> It seems that something locally must be changed.  Bad thing is I have to
> rely on many intermediaries to get answers and get things done.
>
> Paul




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26328&t=26263
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



RE: Latency on the local access circuit [7:26263]

2001-11-14 Thread Paul Jin

Hi Alex,

This site has another router connection back to the hub so this PVC is not
being used at this moment except for testing.

I have no fecn/becns.  I have the CIR set at 128K on the network portion.

No discards within the cloud.  in fact, within the network, it is
around 70 ms between stratacom to stratacom.  But between the router
to router ping, it is very abnormally high.  

The hub site has other PVCs exiting to other routers and they all
work ok.  Just this particular one.

It seems that something locally must be changed.  Bad thing is I have to
rely on many intermediaries to get answers and get things done.

Paul




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26316&t=26263
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]



RE: Latency on the local access circuit [7:26263]

2001-11-14 Thread Alex Lei

Paul,

I have a feeling that you might have tried the below, but just for a
suggestion:

Is the ping time always high, or does it vary depending on the time of the
day? If it's the latter, it might be a congestion problem, and you can check
for the presence of FECN's on the frame switch. This happened to me once,
and it turned out to be an incorrect CIR on the PVC.

Alex


Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26300&t=26263
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html