Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-28 Thread WEAVER, Simon (external)

I tend not to use the msi file extension, but rather the .exe file
itself.

Is that not present?
Cant be the OS if its running ok - any other error messages in the event
log itself? 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: Wednesday, August 27, 2008 2:09 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi,

I've run the .msi installer and it gives me the below error message
Error 1723, There is a problem with this window installer package. A DLL
required for this install to complete could not be run. 

Is there something wrong with the OS?

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure.
If you are not the intended recipient, please notify the sender
immediately, do not copy this message or any attachments and do not use it
for any purpose or disclose its content to any person, but delete this
message and any attachments from your system. Astrium disclaims any and all
liability if this email transmission was virus corrupted, altered or
falsified.
-
Astrium Limited, Registered in England and Wales No. 2449259
REGISTERED OFFICE:-
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread WEAVER, Simon (external)

I would also delete the veritas registry key to ensure a fresh install.

Simon
P.S. hkey_local_machine\software\ VERITAS

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Martin,
Jonathan
Sent: Tuesday, August 26, 2008 1:38 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] NBU6.5 Win Client Installation

I've gotten this but I can't exactly remember how I fixed it.  I would
try: Reboot, Delete everything in C:\Program Files\Veritas and run the
.msi installer file not the setup.exe

-Jonathan 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: Tuesday, August 26, 2008 3:19 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi all,

Anyone experience while installing NBU 6.5 Window Client on
Window2000SP4 machine, during validaing install process, the
installation failed and an message saying the process was interupted.

We check the event viewer of the machine and we saw an error message
saying cannont connect to server.

This is the only win2k SP4 machine that is having this problem, the rest
of the machines are ok. Strangely enough, i've tried installing NBU6.0
client onto it and it went through but when i tried to upgrade it to
NBU6.5, it failed with the same error message.

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure.
If you are not the intended recipient, please notify the sender
immediately, do not copy this message or any attachments and do not use it
for any purpose or disclose its content to any person, but delete this
message and any attachments from your system. Astrium disclaims any and all
liability if this email transmission was virus corrupted, altered or
falsified.
-
Astrium Limited, Registered in England and Wales No. 2449259
REGISTERED OFFICE:-
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread dy018

Hi,

I've run the .msi installer and it gives me the below error message
Error 1723, There is a problem with this window installer package. A DLL 
required for this install to complete could not be run. 

Is there something wrong with the OS?

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread Spearman, David
Use setup, not the msi installer

David Spearman
County of Hnerico

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: Wednesday, August 27, 2008 9:09 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi,

I've run the .msi installer and it gives me the below error message
Error 1723, There is a problem with this window installer package. A DLL
required for this install to complete could not be run. 

Is there something wrong with the OS?

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread dy018

Hi Thanks for your reply,

Using the exe was what we did in the first place, i'm jus trying out installing 
using the .msi as suggested by Martins to see if there's any difference but 
apparently still the same problem but different error messages.


Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread Marianne Van Den Berg
Look for errors in the install log. 

Extract from TechNote http://seer.support.veritas.com/docs/270110.htm:

Review the install log file for errors.  The install log file is found
in the C:\Documents and Settings\administrator_userid\Local
Settings\Temp directory.


Also have a look at these TechNotes:
http://seer.support.veritas.com/docs/283611.htm

http://seer.entsupport.symantec.com/docs/300515.htm


Regards

M.

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: 27 August 2008 16:24
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi Thanks for your reply,

Using the exe was what we did in the first place, i'm jus trying out
installing using the .msi as suggested by Martins to see if there's any
difference but apparently still the same problem but different error
messages.


Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu



___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread Haskins, Steve
Hello,

Try renaming Netbackup.dll then re-run the installation.

Regards.

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: Wednesday, August 27, 2008 6:09 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi,

I've run the .msi installer and it gives me the below error message
Error 1723, There is a problem with this window installer package. A DLL
required for this install to complete could not be run. 

Is there something wrong with the OS?

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread dy018

Hi, do you mean renaming netbackup.dll to any other name before running the 
install?

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread Haskins, Steve
Yes, such as Netbackup.org or Netbackuporg.dll. This if your error
message also contains text stating to close Netbackup processes and try
again.
I have also discovered it best to use the local admin account as my
personal account gives an error since my home folder mapped drive
changed to a different location and the installer is looking for that
drive location from its record in the registry (or deleting my profile
off the servers works).

These are all Windows scenarios.

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: Wednesday, August 27, 2008 10:55 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi, do you mean renaming netbackup.dll to any other name before running
the install?

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] NBU6.5 Win Client Installation

2008-08-27 Thread dy018

The netbackup.dll i think only existing after installation (correct me if i'm 
wrong), i do not find any netbackup.dll file in the installation CD. Right now 
i'm not able to install the netbackup client. After looking thru the 
installation log, below are the last 2 line where it stop during validating 
install.

08-27-2008,19:20:53 :  Property(S): ServicesFileName = 
c:\winnt\system32\drivers\etc\services
08-27-2008,19:20:53 :  Action ended 19:20:53: INSTALL. Return value 3.

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] NBU6.5 Win Client Installation

2008-08-26 Thread dy018

Hi all,

Anyone experience while installing NBU 6.5 Window Client on Window2000SP4 
machine, during validaing install process, the installation failed and an 
message saying the process was interupted.

We check the event viewer of the machine and we saw an error message saying 
cannont connect to server.

This is the only win2k SP4 machine that is having this problem, the rest of the 
machines are ok. Strangely enough, i've tried installing NBU6.0 client onto it 
and it went through but when i tried to upgrade it to NBU6.5, it failed with 
the same error message.

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NBU6.5 Win Client Installation

2008-08-26 Thread Martin, Jonathan
I've gotten this but I can't exactly remember how I fixed it.  I would
try: Reboot, Delete everything in C:\Program Files\Veritas and run the
.msi installer file not the setup.exe

-Jonathan 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of dy018
Sent: Tuesday, August 26, 2008 3:19 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] NBU6.5 Win Client Installation


Hi all,

Anyone experience while installing NBU 6.5 Window Client on
Window2000SP4 machine, during validaing install process, the
installation failed and an message saying the process was interupted.

We check the event viewer of the machine and we saw an error message
saying cannont connect to server.

This is the only win2k SP4 machine that is having this problem, the rest
of the machines are ok. Strangely enough, i've tried installing NBU6.0
client onto it and it went through but when i tried to upgrade it to
NBU6.5, it failed with the same error message.

Regards

+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to [EMAIL PROTECTED]
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu