From: Af [mailto:af-boun...@afmug.com] On Behalf Of Forrest Christian (List
Account)
Sent: Sunday, December 31, 2017 2:38 AM
To: af
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
You can also
t;
> I would work out ohms law on it to make sure.
>
> Do you need to run data over the CAT 5?
>
> If not, you really don’t need the CMM5, just connect all the wires of
> similar polarity and connect direct to the power supply.
>
>
>
> *From:* Andreas Wiatowski
>
>
.@wbmfg.com"
*Reply-To: *"af@afmug.com"
*Date: *Friday, December 29, 2017 at 11:06 AM
*To: *"af@afmug.com"
*Subject: *Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
I would work out ohms law on it to make sure.
Do you need to run data over the CAT 5?
If not,
that still works and if it doesn�t, Chuck�s
would.
Rory
*From:*Af [mailto:af-boun...@afmug.com] *On Behalf Of *Gino A. Villarini
*Sent:* Friday, December 29, 2017 10:22 AM
*To:* af@afmug.com
*Subject:* Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
Yeah but it requires over 50W
> dissemination, copying, or storage of this message or its attachments is
> strictly prohibited.
>
>
>
>
>
> *From: *Af on behalf of "ch...@wbmfg.com" <
> ch...@wbmfg.com>
> *Reply-To: *"af@afmug.com"
> *Date: *Friday, December 29, 2017
¿½m pretty sure that still works and if it doesn�t, Chuck�s
would.
Rory
*From:*Af [mailto:af-boun...@afmug.com] *On Behalf Of *Gino A. Villarini
*Sent:* Friday, December 29, 2017 10:22 AM
*To:* af@afmug.com
*Subject:* Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
Yeah but it
On 12/30/17 7:50 AM, Rory Conaway wrote:
The 450M needs 50w? I thought only the AirFiber needed that much power.
Keep in mind that this cable is 23G. Without running the numbers, I’m
pretty sure that still works and if it doesn’t, Chuck’s would.
The 450m is like 7x radios in a single case
Villarini
Sent: Friday, December 29, 2017 10:22 AM
To: af@afmug.com
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
Yeah but it requires over 50W iirc vs a UBNT AP 8-10w
From: Af mailto:af-boun...@afmug.com>> on behalf of Rory
Conaway mailto:r...@triadwireless.net>&
:22 PM
To: "af@afmug.com<mailto:af@afmug.com>" mailto:af@afmug.com>>
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
Isn’t the 450m 48v?
Rory
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Gino A. Villarini
Sent: Friday, December 29, 2017 9:19 AM
To: af@
9, 2017 9:43 AM
To: af@afmug.com
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
We need power and timing, but no data… hence the CMM5.
Cheers,
Andreas Wiatowski, CEO
Silo Wireless Inc.
1-866-727-4138 x-600
http://www.silowireless.com<http://www.silowireless.com/>
Wire
.com
> *Subject:* Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
>
>
> We need power and timing, but no data… hence the CMM5.
>
>
>
> Cheers,
>
>
>
> Andreas Wiatowski, CEO
>
> Silo Wireless Inc.
>
> 1-866-727-4138 x-600 <(866)%20727
"
Reply-To: "af@afmug.com"
Date: Friday, December 29, 2017 at 11:47 AM
To: "af@afmug.com"
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
Do you already have the CMM5? If not I would use Packetflux.
From: Andreas Wiatowski
Sent: Friday, Decemb
Do you already have the CMM5? If not I would use Packetflux.
From: Andreas Wiatowski
Sent: Friday, December 29, 2017 9:43 AM
To: af@afmug.com
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
We need power and timing, but no data… hence the CMM5.
Cheers,
Andreas
quot;af@afmug.com"
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
I would work out ohms law on it to make sure.
Do you need to run data over the CAT 5?
If not, you really don’t need the CMM5, just connect all the wires of similar
polarity and connect direct to the power s
Isn't the 450m 48v?
Rory
From: Af [mailto:af-boun...@afmug.com] On Behalf Of Gino A. Villarini
Sent: Friday, December 29, 2017 9:19 AM
To: af@afmug.com
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
Power consumption from the 450M is very different form a UBNT Uni
day, December 29, 2017 at 12:04 PM
To: "af@afmug.com<mailto:af@afmug.com>" mailto:af@afmug.com>>
Subject: Re: [AFMUG] 450M maximum length of Cat5e (Just for power)
If you use 23G Cat-6, you should be fine. We just connected a Ubiquiti Unifi
radio at 490’ and it’s running
Subject: [AFMUG] 450M maximum length of Cat5e (Just for power)
Good Morning,
We have a couple of large towers where we will be installing 450M with fibre.
To power we, would like to use the CMM5 , but we are unsure if we can power the
M sufficiently over such a long CAT 5 run. Does anyone
@afmug.com
Subject: [AFMUG] 450M maximum length of Cat5e (Just for power)
Good Morning,
We have a couple of large towers where we will be installing 450M with fibre.
To power we, would like to use the CMM5 , but we are unsure if we can power the
M sufficiently over such a long CAT 5 run. Does anyone
Good Morning,
We have a couple of large towers where we will be installing 450M with fibre.
To power we, would like to use the CMM5 , but we are unsure if we can power the
M sufficiently over such a long CAT 5 run. Does anyone have the answer to
this? We could see cat5 runs (Shielded and gell